Fcu screwfix. £ 13. Fcu screwfix

 
 £ 13Fcu screwfix  I can tell you that either the lighting circuit is a high amperage, or and it definately isnt a power shower as they use about 40 AMPS

you cannot run spur to spur with sockets incase of over load of cable but. Home Forums > Screwfix Community Forum > Electricians' Talk > Double pole switch without FCU Discussion in ' Electricians' Talk ' started by DoItYoung , Feb 9, 2021 . There is no accessory correctly called a fused spur - it is just a common name for them. Skip to content. comes with a plug, so it can be disconnected. MK FCU Switches & Sockets (17 products) Categories Fused Spurs (17) Filters (1 applied) Clear all Brand British General (27) Crabtree (26) Essentials (4) LAP (33) MK (17). Plug the 3 pin end into RCD socket. com. Instructions for the alarm state 2A fcu, Fair enough if off a ring but I've dedicated a B6 MCB on the 100mA side of. Login to Online Banking. Information and resources to make well-informed financial decisions. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU for lights but not sockets on spur? Discussion in 'Electricians' Talk' started by Mr. Power Indicator. Last Day: Grab DeWalt safety boots and clothing with 10% off at Screwfix. woodbutcherbower, Dec 2, 2021. then when the work as been done get my electrian to sign off & check it. wally, Nov 28, 2007 #81. Is there any reason that this FCU can't be fixed, by a surface mounted box, to the top of the unit instead of cutting a hole in the back of the unit. Assume this is quite normal and no different if the FCU's were to be replaced with sockets. Handyandy, Nov 27, 2007 #36. The light switch, again, like the socket, had a FCU installed just before the switch. Buy any 10+ Save 10% - View Offer. I have had an electrician install a spurred FCU in the loft in preparation for a boiler to be. 48 Inc Vat. Learn More. Terminal Capacity. 5mm² overload ? Mr. Without RCD. 60 days free credit available. 5 mm sq cable is normally rated around the 20 amp mark, so you need to ensure you can't draw more than 20 amp. Similarly the pump will only pull 2. The most practical way IMHO is to install a single socket in an adjacent base unit so you can plug in the hob ignition. Each socket on the ring is allowed 1 spur off it. com. However, this is frowned upon as poor practice. 51 Inc Vat. Skip to content. You said you are not a spark. In my opinion it's no different to using 2. Available in a variety of options. com, Where the Trade Buys . acca Guest. 5 mm. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. Bathroom fan is isolated via a 4g grid switch unit but has an FCU with 3A fuse instead of a switch, located on landing. Order MK Logic Plus 13A Switched Fused Spur & Flex Outlet White at Screwfix. 84 Inc Vat. The plate is ok if a connection is needed there of course but the flex fitted to the towel rail usually plenty long enough to go through the wall and into the fcu. But if you then inserted a 9th socket somewhere in the ring, all of a sudden it would be OK, even though it is blindingly obvious that the mere. Would it be ok to replace a single socket on ring main with an FCU to run a fridge? jimany, Nov 24, 2023 at 9:02 AM #1 All of the lines and rectangles in RED are the existing 2. Discussion in 'Electricians' Talk' started by klunky, Dec 22, 2019. Therefore I am proposing: 2. Free next day delivery available. Cold Water Tank 25gal 690 x 515 x 520mm, at Screwfix. Tbh what you plan there is do-able but it's a bit of a weird way of doing it. What is common practice is a FCU mounted 150-200mm from the side of the finished chimney with a 1mm T/E buried in the wall from the FCU (fusedd at 3A) at 90 degree's which then exits the plaster dead centre inside the chimney location which can then be junctioned box'd on to the flying lead inside the. Need Help. com. My plan was to use 2. KC DIY New Member. I am trying to find a 2 gang wall outlet with a single socket and FCU combination. Without Flex Outlet. com. 5mm², 2 x 4mm² or 1 x 6mm² cables. Captive Terminal Screws. Discussion in ' Electricians' Talk ' started by ScubaCollie, Jul 2, 2021 . The only way I can see to do this is to remove the cable from the adjacent double socket feeding the spur and to replace it with a plug and flex to the spur instead. Bazza, Aug 30, 2020 #9. 5mm² cables. “From this I intend to spur to an adjacent switched 5 A fused FCU supplying a shower pump. Temperature Range. £27. Have a redundant supply in bathroom cupboard, fed in 2. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. Alaska USA Federal Credit Union, founded in 1948, is a member-owned, not-for-profit cooperative, with a full range of financial services, including checking and savings accounts, consumer loans, real estate loans, mortgage loans, credit cards, business services and personal insurance. com. I now need another socket on the other side of the garage. That is fully Regs compliant. £79. The cable or flex attached to the gas fire is purely to supply the ignition. With Flex Outlet. Without RCD. Some say if the applicance is freestanding and has a moulded 13A plug, it doesn't require an FCU. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . The flex provided is not rated to 13A because the ignition requires very little current and so the flex requires protection by a 3A fuse. Add the account you wish to pay from. Free next day delivery available. Screwfix customers rate this product 4. Terminals accept 3 x 2. Supplied with four screw cap covers for a sleek profile finish. 800. £8. Credit Human CD changes: 6-11 month 5. 5mm swa cable and have it coming out of the house and run along the wall into the shed. Change the single box to a dual 35mm box. uPVC Construction. terrymac, Oct 6, 2019. 5 for the ring leaves 1 x 2. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. bearing in mind the supply is 6mm cable do you guys have. Captive Terminal Screws. Delivery 7 days a week. Stay updated with promo codes and voucher codes for November 2023. Terminals accept 3 x 2. £13. CCX Plywood, 3/4 in x 4 ft x 8 ft - Southern Pine, Pressure Treated. Having done that, you could fit a 13A fused spur for the immersion heater (hard-wired) with an adjacent 2-gang socket for TV & shower - not spurred from the FCU, but incorporated into the ring by taking one of the existing cables to the immersion spur and the other to the socket - with a short link between the two to maintain the ring -continuity. I've no idea yet. . - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. Buy MK FCU Switches & Sockets at Screwfix. I would not have a socket in an ordinary size bathroom, especially in a rented house. So do we agree then that an fcu can be fed from a ring in 1. This is to feed the extractor fan. Apple Pay accepted in store. Don't buy Volex rubbish, buy MK or. PAGE 1 OF 5. Raised Slim Profile. So what you're saying is one ring tail would connect to the supply terminals on the fcu. Follow the remaining on screen instructions to accept the terms and agreements and. From the settings menu, click or tap on 'Push Notifications'. PVC cement had crossed my mind, but not sure if you can apply that over an existing joint. touc New Member. Order MK Metalclad Plus 13A Unswitched Metal Clad Fused Spur with White Inserts at Screwfix. Browse store. We'll that's what I've always used when I've done outside pond jobs. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . The idea is that if you take out the fuse, it would stop the dryer from working for sure. Choose from top trade brands. With RCD. 30 day money back guarantee. £ 5. com. Screwfix Direct DIY, Paint Supplies: Shop Online at Screwfix Direct Home Improvement for UK Paint Supplies. Joe Public don't understand that switching off a circuit can be used to isolate a cooker hood. Trips at 30mA. If you want to protect the fan wiring with a 3A FCU or whatever, you could put a cheaper 2 pole FCU on the live/neutral feed to the lighting, saves the expensive of having a 3 pole switch just for the fan. spirits are real 2016 Screwfix Select. View all: MK Fused Spurs. I currently have an FCU supplying ONE outside PIR security light. Headquartered in Gainesville, FL, it has assets in the amount of $315,007,913. com. Check stock, order online & collect in as little as 1 minute. Keep your accounts at your fingertips by downloading our FREE mobile banking app. Flex Outlet. com. 5mm2 spur from socket. FREE next day delivery available, free collection in 1 minute. Order British General 900 Series 13A Switched Fused Spur with LED White at Screwfix. 3/5. View and enroll in eStatements. Hob wago connectors diynotDoes an electric oven craving to be hardwired Wiring in new oven and induction hob. This little piece of 1. Terminal Capacity. Identify FCU suppling alarm. Hi all, I've installed an LED floodlight vertically above an FCU switch, and used some 25mm conduit and fittings that I already had. On the load side connect a 2. With RCD. So not sure how the one at the front is powered together with 'login/password unit' in the hallway. I also think it looks like part of a RCD, it may connect to the moulded breaker, I remember us having a lot of them in weather proof distribution units, but seem to remember they has a small unit between the two where you can set time delay and leakage current, went up to 1 minute and 5 amp. If the fcu is fused at 13A, can the 1. Order LAP 13A Switched Fused Spur Brushed Stainless Steel with White Inserts at Screwfix. Sign in / Register. Sign up to receive exclusive offers, vouchers and deals. That FCU will then be connected to the TV socket and another socket for the virgin box. Without RCD. Put one there specifically. Hi guys got 3 klima 5m 750 watt heating Matt's in a kitchen. See item 30624. Option 2. Space to mount the new socket and FCU is pretty tight and it'll be very visible from the patio. . Identify FCU suppling alarm. Ideally I'd like to run a cable from the FCU in one direction with two double sockets daisy chained and another cable in the opposite direction with one double socket. Cheers mate. Terminals accept 3 x 2. KC DIY, Jun 24, 2021. Over 40,000 products. One for the extra sockets, and the other for the batten light. Order Schneider Electric Ultimate Low Profile 13A Switched Fused Spur Brushed Chrome with Black Inserts at Screwfix. Need Help. Hundreds of stores nationwide. Screwfix Community Forum. The external sockets for the hot tub are at the exact opposite end of the garage from the LED light socket. Greetings, my wife would like a double gang socket in the potting shed for her heat mat for the plants and other very low voltage items with no lighting required - just a double gang socket. Can I do any of the following and maintain compliance with the regs? My preferred plan: Connect in an external IP54+ 3A FCU via the (feed or switch?) @ 13A FCU with appropriate cable (1. Ho hum such is the way of things. Buy FCU Switches & Sockets at Screwfix. Let us help you with a pre-approved auto loan to ensure you know how much you can afford before you buy. Select the loan you wish to pay. Screwfix Community Forum. Requires 25mm Back Box. FREE next day delivery available, free collection in 1 minute. , Suite 103, San Fernando, CA 91340-3618 is Officially OPEN to Public. and much more. My reason for down rating would be that 10mm cable which is what the shower circuit is wired in, is exspensive and a pain to work with but I see your point. Discussion in 'Electricians' Talk' started by dabhand, Jul 24, 2007. Requires 25mm Back Box. Discussion in 'Electricians' Talk' started by Jim, Mar 31, 2005. Added protection against electric shock. My question is, without taking it apart again what's the best way to seal the FCU housing to the conduit female accessory, and also the conduit to the female accessory. One main cable ONLY contains a red cable: next 2 main cables contain a black and earth each. Screwfix customers rate this product 4. I've heard. Terminals accept 3 x 2. The UK’s leading retailer of trade tools and hardware. Screwfix Community Forum. 036 cable. I turned the switch on and off a few times, there was a bit of a fizzle noise while the spur tried to come on, So I changed the fuse in the spur, although the old fuse had not blown. 5mm2 through wall to light. Actually they are all correctly called fused connection units (FCUs). You still haven't answered the queston of how many spurs you think is acceptable from a single point. Worth mentioning that I've drilled a drain hole in the FCU. Or under the bath, with a panel fitted that requires a tool (screwdriver) to remove panel (say for a shower pump/whirlpool bath)Bazza-spark Screwfix Select. com. Home Forums > Screwfix Community Forum > Electricians' Talk > Replacing 13 amp double socket with 2 FCU's. All loans subject to credit approval. We offer a wide range of services at no-cost or at lower costs than traditional financial institutions, including more favorable rates on dividends and loans. Terminal Capacity. The fused spur switch light came on fine but as soon as I plugged in the washing. Can't see any issue with having an FCU as part of the ring - the ones in the kitchen for fridge, washer etc are wired that way for example. Masterseal IP56 13A Sw FCU, at Screwfix Direct Masterseal range has been specifically designed for use either outdoors or indoors and in areas heavily exposed to dust and splashing water. 5mm2 through wall to socket. There is very little wall space to chase out more space for extra switches. Hi. FlyByNight , Jan 12, 2021At the shed the spur is protected again by a switched spur before feeding the light and 1 socket. 5mm T/E through the wall to a 13A switched FCU or Timer module. Spur off socket to unswitched FCU From unswitched FCU to a switched FCU (needed for functional switching of fly zapper) The load side of SFCU going to the fly zapper and from feed side of SFCU to another SFCU to power outside light. 40m/sec Trip Speed. Buy online & collect in hundreds of stores in as little as 1 minute! Free returns. Order online at Screwfix. Deleted member 11267, Apr 23, 2018. Choose from top trade brands. 5mm swa cable and have it coming out of the house and run along the wall into the shed. Flex Outlet. The radial is in 2. Terminals accept 3 x 2. Pay your way. Search; Your Account Sign in. com. #4. Yes of course there is. I vote with UN - 2 pole RCBOs and radials Comlec, Mar 10, 2018 #22. So my new kitchen cupboards are 10mm less depth than the old which has created a problem for my plug in Intergrated oven. We offer safe deposit boxes in a variety of sizes to keep your important papers and valuables safe. Terminal Capacity. unphased, Mar 10, 2018 #21. Sign in / Register. But I have a three gang switch that each one goes off outside to different lights (previous owners not me who put them in). 0mm cable you have fulfilled all the requirements of the regulations as long as it is okay for volt drop and you have used water-proof glands (CW type). 0°C to 40 °C. 5mm² or 2 x 4mm² cables. 5mm cables via wago connectors. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. FREE next day delivery available, free collection in 1 minute. Page 3 of 3 < Prev 1. com. Comlec Screwfix Select. L1 is listed in the instructions as the live for the slave luminaire. Evening all, I have an old airing cupboard above the kitchen with an immersion heater radial in it that is no longer used as we have a combi. Worth mentioning that I've drilled a drain hole in the FCU. The extractor fan does not have and require a earth wire. I charge them for doing a good first rate job. Visit from any device — desktop, mobile, or tablet. Order online at Screwfix. 5mm. I’m fairly sure that you’ve misunderstood the reply from Comlec The OP asked about fitting an FCU to power a light fitting from socket Comlec suggested fitting a S (switched) FCU as that saves fitting a separate light switch -. 1. Ind spark, Sep 15, 2023. adambaz Standard Member. Buy MK FCU Switches & Sockets at Screwfix. com. Then from the socket terminals the second ring tail would connect, thus completing the circuit/ring. The easiest way I can see to do this (without extending the boiler load cable, making additional hole and moving the FCU due to cable length) is to run an additional cable from the supply side of the FCU to the socket above through the. Log into your online banking account from your computer and go to the eDocs widget. Electrican has done the following, but isn't. 112, Dec 23, 2019. Without RCD. That's two cables on the 'load' side of the FCU. Can’t advise properly unless you can be more specific. Passive operation. #9. com. com. As you have spured from the socket in 4. 89Inc Vat. spirits are real 2016 Screwfix Select. 5mm2 2 core and earth. Terminal Capacity. An FCU is not switchgear. Lectrician Screwfix Select. What is your opinion on this workmanship, I think it is shabby and very unprofessional but the FCU is 2 inches away from the side of the boiler and 15cm horizontally away from the the gas cooker hobs and vertically 40cm high from the cookers hobs. There is a $10 refundable key deposit on each box. 5mm I'm guessing at 3a) to do so. British General Evolve 13A Unswitched Fused Spur with LED Blue with Black Inserts (308PX) compare. I spurred off this socket a few months ago in 2. to nearby 13amp fused isolation switch. 1400W. Oven gas freestanding 90cm hob cooker award nz hobs choose board. you cannot run spur to spur with sockets incase of over load of cable but. When you think most people typically wire a spur using 2. 3. Minimum 3mm switching contact gap. PayPal accepted online. Buy any 10+ Save 10% - View Offer. Most integrated dishwashers have a recess at the base so the cable, infeed and waste pipe can be sat directly behind it at floor level and passed through the decor panel/service void into the cabinet socket/plumbing. Products reviewed by the trade and home improvers. Display transactions and related information. Combi boiler needs FCU to make it feel complete (RCD protected now it seems) but it is in the bathroom. As the feed to the outbuilding comes from an FCU, the max current is limited to 13amps. In the case of what I'm suggesting, the FCU is the "accessor (y) to BS 1363" being supplied through the RFC. 433. Can I tell him he`s talking c**p or not. PayPal accepted online. Hans_25 said: ↑. com. What I have in place atm is a 3 amp FCU in the loft spurred from what I believe is the switch box for the immersion heater. The UK’s leading retailer of trade tools and hardware. from a ring circuit it is ok to feed from the ring to the. Trips at 30mA. ie. Satisfied no power, then remove lid on alarm panel. As you have spured from the socket in 4. ? thanks for any input / help lads. Requires 35mm Back Box. See pic for context. Latched with no need to reset after a loss of power. Transfers. Order British General IP66 13A Weatherproof Outdoor Switched Fused Spur & Flex Outlet with Neon at Screwfix. Coloumb Screwfix Select. You made that up. You could fit a double + single box in place of the double socket. 25Ltr Dry Capacity. With Flex Outlet. 5 from the load side of this spur with a 13 amp fuse into the supply side of a spur in the right hand side of the box. Also, if any circuit needed work doing on it, the electrician could have limited access ( depending on the size of the cupboard) Ask a question. Many. Requires 35mm Back Box. The idea is that if the fan jambs it will draw excessive current which will blow the 3 amp fuse before the fire starts! seneca,May 16, 2015. This is perfectly OK, according to the regs. Latched with no need to reset after a loss of power. Screwfix Community Forum. So he helped me swap out the wagos and run a 1. Discussion in 'Electricians' Talk' started by sparky308, Nov 5, 2005. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesTickets are now sold out for Hozier ’s May 21, 2024, performance at the Empower FCU Amphitheater in Syracuse. $54. Hi all, Just looking for a bit of reassurance here! If an FCU is being used to feed a small load such as an outside light etc. ”. Home Forums > Screwfix Community Forum > Electricians' Talk > Switch FCU (LED not working) Discussion in 'Electricians' Talk' started by sp383, Nov 13, 2018. 6amp breaker for the lights and a 16amp breaker for the couple. unphased Screwfix Select. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of products. spirits are real 2016, Feb 24, 2021. Schneider Electric Lisse Deco 13A Switched Fused Spur & Flex Outlet with LED Polished Chrome with Black Inserts (119FF) (2) compare. What will you make up next? Don't keep on. Screwfix customers rate this product 4. For example, with Screwfix Direct Catalogue, you can buy all kinds of high quality building materials, and maintenance and refurbishment items. ie. Discussion in 'Electricians' Talk' started by touc, Feb 14, 2005. Cleat it to the wall and then gland it into the socket. 5mm², 2 x 4mm² or 1 x 6mm² cables. - - - - Call 24/7 on: 03330 112. Once inside the shed put the swa inside a junction box and connect it to two 2. Use a 3A fuse on the fcu. Put one there specifically. PayPal accepted online. Triton Thermostatic Mixer Shower Valve 266 x 60 x 50mm, at Screwfix. FREE next day delivery available, free collection in 1 minute. Many. Wellwisher, Sep 11, 2023. The electrician that came round explained that he'd replace the double socket on the wall of the utility room/study (2nd photo), with 2 FCU's. 80%>6. 51 Inc Vat. Without RCD. Then establish if the two cables connected to the FCU's supply terminals are part of a ring final ,or a radial circuit. Order online at Screwfix. 26 Inc Vat. Wood. My question is, without taking it apart again what's the best way to seal the FCU housing to the conduit female accessory, and also the conduit to the female accessory. I told you what we were trained in.